Cisco 2800 Series |
Cisco 2801 |
Cisco 2811 |
Cisco 2821 |
Cisco 2851 |
|
Product Architecture |
|||||
DRAM |
• Default: 128 MB
• Maximum: 384 MB
|
• Default: 256 MB
• Maximum: 768 MB
|
• Default: 256 MB
• Maximum: 1 GB
|
||
Compact Flash |
• Default: 64 MB
• Maximum: 128MB
|
• Default: 64 MB
• Maximum: 256 MB
|
|||
Fixed USB 1.1 Ports |
1 |
2 |
|||
Onboard LAN Ports |
2-10/100 |
2-10/100/1000 |
|||
Onboard AIM (Internal) Slot |
2 |
||||
Interface Card Slots |
• 4 slots; 2 slots support HWIC, WIC, VIC, or VWIC type modules
• 1 slot supports WIC, VIC, or VWIC type modules
• 1 slot supports VIC or VWIC type modules
|
4 slots, each slot can support HWIC, WIC, VIC, or VWIC type modules |
|||
Network-Module Slot |
No |
1 slot, supports NM and NME type modules |
1 slot, supports NM, NME and NME-X type modules |
1 slot, supports NM, NME, NME-X, NMD and NME-XD type modules |
|
Extension Voice Module Slot |
0 |
1 |
|||
PVDM (DSP) Slots on Motherboard |
2 |
3 |
|||
Integrated Hardware-Based Encryption |
Yes |
||||
VPN Hardware Acceleration (on Motherboard) |
DES, 3DES, AES 128, AES 192, and AES 256 |
||||
Optional Integrated In-Line Power (PoE) |
Yes, requires AC-IP power supply |
||||
Console Port |
1 |
||||
Auxiliary Port |
1 |
||||
Minimum Cisco IOS Software Release |
12.3(8)T |
||||
Rack Mounting |
Yes, 19-inch |
Yes, 19- and 23-in. options |
|||
Wall Mounting |
No |
Yes |
No |
No |
|
Power Requirements |
|||||
AC Input Voltage |
100 to 240 VAC, autoranging |
||||
AC Input Frequency |
47-63 Hz |
||||
AC Input Current |
2A (110V) 1A (230V) |
3A (110V) 2A (230V) |
|||
AC Input Surge Current |
50A maximum, one cycle (-48V power included) |
||||
AC-IP Maximum In-Line Power Distribution |
120W |
160W |
240W |
360W |
|
AC-IP Input Current |
4A (110V) 2A (230V) |
8A (110V) 4A (230V) |
|||
AC-IP Input Surge Current |
50A maximum, one cycle (-48V power included) |
||||
DC Input Voltage |
No DC Power Option available |
24 to 60 VDC, autoranging positive or negative |
|||
DC Input Current |
• No DC Power Option available
|
• 8A (24V)
• 3A (60V)
• Startup current 50A<10 ms
|
• 12A (24V)
• 5A (60V)
• Startup current 50A<10 ms
|
||
Typical Power Dissipation (No Modules) |
42W (143 BTU/hr) |
32W (109 BTU/hr) |
54W (184 BTU/hr) |
58W (197 BTU/hr) |
|
Power Dissipation-AC without IP Phone Support |
150W (511 BTU/hr) |
170W (580 BTU/hr) |
280W (955 BTU/hr) |
280W (955 BTU/hr) |
|
Power Dissipation-AC with IP Phone Support-System Only |
150W (511 BTU/hr) |
210W (717 BTU/hr) |
310W (1058 BTU/hr) |
370W (1262 BTU/hr) |
|
Power Dissipation-AC with IP Phone Support-IP Phones |
180W (612 BTU/hr) |
160W (546 BTU/hr) |
240W (819 BTU/hr) |
360W (1128 BTU/hr) |
|
Power Dissipation-DC |
Not applicable |
180W (614 BTU/hr) |
300W (1024 BTU/hr) |
300W (1024 BTU/hr) |
|
RPS |
No |
External only, connector for RPS provided by default |
|||
Recommended RPS Unit |
No RPS option |
Cisco RPS-2300 Redundant Power System |
|||
Environmental Specifications |
|||||
Operating Temperature |
32° to 104°F (0° to 40°C) |
||||
Non-Operating Temperature |
-4° to 149°F (-20° to 65°C) |
-40° to 158°F (-40° to 70°C) |
|||
Maximum Operating Temperature at Altitude |
• 40°C @ sea level
• 31°C @ 6,000 ft
(1800 m) • 25°C @ 10,000 ft (3000 m)
Note: Derate 1.5°C per 1000 ft |
• 40°C @ sea level
• 40°C @ 6,000 ft
(1800 m) • 30°C @ 13,000 ft (4000 m)
• 27.2°C @ 15,000 ft (4600 m)
Note: Derate 1.4°C per 1,000 ft above 6,000 ft |
|||
Operating Humidity |
10 to 85% RH non-condensing |
5 to 85%RH, non-condensing |
|||
Dimensions (H x W x D) |
• 1.72 x 17.5 x 16.5 in.
• (43.7 x 445 x 419 mm)
|
• 1.75 x 17.25 x 16.4 in.
• (44.5 x 438.2 x 416.6 mm)
|
• 3.5 x 17.25 x 16.4 in.
• (88.9 x 438.2 x 416.6 mm)
|
||
Rack Height |
1 rack unit (1RU) |
2RU |
|||
Weight (Fully Configured) |
13.7 lb (6.2 kg) |
14 lb (6.4 kg) |
25 lb (11.4 kg) |
||
Noise Level (Min/Max) |
• 39 dBA for normal operating temperature (<90°F/32.2°C)
• 53.5 dBA (@ maximum fan speed)
|
• 47 dBA for normal operating temperature (<90°F/32.2°C)
• 57 dBA (@ maximum fan speed)
|
• 44 dBA for normal operating temperature (<90°F/32.2°C)
• 53 dBA (@ maximum fan speed)
|
||
Regulatory Compliance |
|||||
NEBS |
No |
Yes |
Yes |
||
Safety |
• UL 60950
• CAN/CSA C22.2 No. 60950
• IEC 60950
• EN 60950-1
• AS/NZS 60950
|
||||
Immunity |
• EN300386
• EN55024/CISPR24
• EN50082-1
• EN61000-6-2
|
||||
EMC |
• FCC Part 15
• ICES-003 Class A
• EN55022 Class A
• CISPR22 Class A
• AS/NZS 3548 Class A
• VCCI Class A
• EN 300386
• EN61000-3-3
• EN61000-3-2
|
||||
FIPS-2 |
FIPS 140-2 Certification for 2801, 2811, 2821, 2851 |
||||
TELCOM** |
• For all four platforms, Telecom compliance standards depend upon country and interface type. Interfaces comply with FCC Part 68, CS-03, JATE Technical Conditions, European Directive 99/5/EC and relevant TBR's. For specific information see the datasheet for the specific interface card.
• Homologation requirements vary by country and interface type. For specific country information, see the on-line approvals data base:http://tools.cisco.com/cse/prdapp/jsp/externalsearch.do?action=externalsearch&page=EXTERNAL_SEARCH&module=EXTERNAL_SEARCH
|
با استفاده از دکمه سفارش دهی و ارسال درخواست برای فروشنده، می توانید برای خرید این محصول به صورت عمده با فروشنده وارد مذاکره شوید. با پرداخت آنلاین وجه سفارش از ضمانت بازگشت وجه برخوردار می شوید.