Description
Each fiber is enclosed in a 0.9mm made of a thermoplastic polymer. Water swelling glass yarns are used with fibers to strengthen and block cable core from water penetration. Cable core is covered by a Low Smoke, Zero Halogen (LSZH) outer jacket.
Features
2 to 12 fibers
Each fiber is enclosed in a 0.9mm made of a thermoplastic polymer
The are color coded for easy identification
Water swelling glass yarns are employed with the fibers to serve as peripheral strength members and to block the cable core from water penetration
UV resistant, Low Smoke, Zero Halogen (LSZH) compound outer jacket is extruded over the cable core
Specifications
Mechanical and Environmental Characteristics
Test |
Detail Specifications |
Test Procedure |
|
IEC-60794-1- 2 Test Method |
TIA/EIA-455 FOTP No |
||
Maximum Pulling Load 1 |
500 N |
E1 |
33 |
Maximum Operating Load |
60% of pulling load |
E1 |
33 |
Minimum Bending Radius Installation Long Term |
20 x cable O.D 10 x cable O.D |
E11 |
104 |
Max. Compressive Loading |
2,000N |
E3 |
41 |
Repeated Impact |
2.9 N.m (J) 3 x 2 impacts |
E4 |
25 |
Twist (Torsion) |
180°x10 times , 125 times the cable O.D. |
E7 |
85 |
Storage Temperature Range |
-20°C to +60°C |
F1 |
3 |
Operating Temperature Range |
-20°C to +50°C
|
F1 |
3 |
Cable Weight and diameter
No of Fibers |
Nom. Cable Outer Diameter (mm) |
Nom. Cable weight (kg/km) |
2 |
4 |
17 |
4 |
5 |
25 |
8 |
6 |
33 |
12 |
7.5 |
45 |
Specifications
Single-Mode Fibers Standard Specifications
|
WHAT IS LSZH?
Low smoke zero halogen or low smoke free of halogen (LSZH or LSOH or LS0H or LSFH) is a material classification typically used for cable jacketing in the wire and cable industry. LSZH cable jacketing is composed of thermoplastic or thermoset compounds that emit limited smoke and no halogen when exposed to high sources of heat, e.g. flame.
Most network cables are insulated with polyethylene,PVC or Thermoplastic Urethane (TPU). In a fire, a halogen-containing plastic material releases,e.g.hydrogen chloride, a poisonous gasthat forms hydrochloric acid when it comes in contact with water.Designated Halogen-free cables , on the other hand, do not produce a dangerous gas/acid combination or toxic smoke when exposed to flame. Low smoke zero halogen cable reduces the amount of toxic and corrosive gas emitted during combustion. This type of material is typically used in poorly ventilated areas such as aircraft or rail cars. Low smoke zero halogen is becoming very popular and, in some cases, a requirement where the protection of people and equipment from toxic and corrosive gas is critical.