حرارت سنج اتونیکس TC4H-24R ساخت کره قیمت مناسب قابلیت ساپورت سنسور تیپ K , J , PT100 و با 1 خروجی رله
حرارت سنجهای اتونیکس ساخت کره با قیمتی مناسب و با قابلیت ساپورت سنسور های تیپ K , J , PT100 و با 1 خروجی رله و یک SSR است در این مدل کنترل کننده با یک سگمنت کار میکند.
Main features
● Realizes ideal temp. controlling with newly developed PID control algorithm and 100ms high speed sampling
● Built-in relay output or SSR output selectable
: Enables to phase control and cycle control with SSR drive output(SSRP function)
● Dramatically increased visibility using wide display part
● Mounting space saving with compact design
: Approx. 38% reduced size compared with existing model(depth-based)
● SV/PV deviation indicatable
Ordering Information
Specification Table
Series TC4S TC4SP TC4Y TC4M TC4W TC4H TC4L
Power supply AC power 100-240VAC 50/60Hz
AC/DC power 24VAC 50/60HZ, 24-48VDC
Allowable voltage range 90 to 110% of rated voltage
Power consumption AC power Max. 5VA(100-240VAC 50/60Hz)
AC/DC power Max. 5VA(24VAC 50/60Hz), Max. 3W(24-48VDC)
Display method 7Segment(Red), Other display(Green, Yellow, Red) LED
Character size W7H15mm W7.4H15mm W9.5H20mm W9.5H20mm W7.0H14.6mm W11H22mm
Input type RTD DPt100(Allowable line resistance max. 5 per a wire)
Thermocouple K(CA), J(IC), L(IC)
Display accuracy※1 RTD, Thermocouple ● At room temperature(23℃5℃): (PV 0.5% or 1℃, select the higher one) 1digit
● Out of room temperature range: (PV 0.5% or 2℃, select the higher one) 1digit
※In case of TC4SP Series, 1℃ will be added.
Control output Relay 250VAC 3A 1 a
SSR 12VDC 2V 20mA Max.
Sub output AL1, AL2 relay output : 250VAC 1A 1a(※TC4SP, TC4Y have AL1 only.)
Control method ON/OFF and P, PI, PD, PID control
Hysteresis 1 to 100C/F(0.1 to 50.0C/F) variable
Proportional band(P) 0.1 to 999.9C/F
Integral time(l) 9999sec.
Derivative time(D) 9999sec.
Control period 0.5 to 120.0sec.
Manual reset 0.0 to 100.0%
Sampling period 100ms
Dielectric strength AC power 2000VAC 50/60Hzfor 1min.(Between input terminal and power terminal)
AC/DC power 1000VAC 50/60Hzfor 1min.(Between input terminal and power terminal)
Vibration 0.75mm amplitude at frequency of 5 to 55Hz(for 1 mln.) In each of X, Y, Z directions for 2 hours
Relay life cycle Mechanical OUT: Over 5,000,000 times, AL1/2: Over 5,000,000 times
Electrical OUT: Over 200,000 times(250VAC 3A resistive load)
AL1/2: Over 300,000 times(250VAC 1A resistive load)
Insulation resistance Min. 100M(at 500VDC megger)
Noise resistance 2kV R-phase, S-phase the square wave noise (pulse width: 1us) by the noise simulator
Memory retention Approx. 10 years (when using non-volatile semiconductor memory type)
Environ-ment -10 to 50℃, storage: -20 to 60℃
35 to 85%RH, storage: 35 to 85%RH
Insulation type Double insulation or reinforced insulation (mark: ▣, Dielectric strength between the measuring input part and the power part: AC power 2kV, AC/DC Power 1kV)
Approval CE, UL (Except for AC/DC power type), RoHS (TC4S)
Unit weight Approx. 97g Approx. 84g Approx. 127g Approx. 127g Approx. 118g Approx. 118g Approx. 172g
※1: Thermocouple L(IC) type, RTD Cu50
● At room temperature (23℃ 5℃): (PV 0.5% or 3℃, select the higher one) 1digit
● Out of room temperature range: (PV 0.5% or 4℃, select the higher one) 1digit In case of TC4SP Series, 1℃ will be added.
※Environment resistance is rated at no freezing or condensation.
Dimensions
Connections
User's Guide
Caution for your safety